Software Quality Engineer

Location
Oxford
Workplace
Hybrid
Employment
Full-time

About this role

ABOUT ORGANOX

OrganOx is a commercial stage organ technology company dedicated to developing technologies to improve outcomes for patients with acute or chronic organ failure. The company was established as a spin out of the University of Oxford in 2008 and is now part of the Terumo Group. OrganOx is a pioneer in normothermic machine perfusion (NMP). It's flagship platform, the metra®, is available for use in the U.S., Europe, Canada, and Australia. It has been utilized in over 7,000 liver transplants to date to keep donor livers in a metabolically active state outside the body enabling longer preservation times and functional assessment of the organ prior to transplant, leading to an increased number of organs available for transplant. Founded in 1921, Terumo Corporation (TSE:4543) strives to fulfil its mission of “Contributing to Society through Healthcare” by providing a comprehensive range of solutions in the fields of therapeutic procedures, hospital operations, and life sciences in more than 160 countries and regions.

Position Summary

The Software Quality Engineer will work closely with R&D, Engineering, Post‑Market Operations and Quality teams to ensure effective control of design, development, risk assessment, and change control.

They will provide Quality and Design Assurance oversight across the software lifecycle for medical devices, including IEC 62304 software and digital health applications. The role works closely with Regulatory Affairs to ensure software documentation and procedures meet applicable standards and regulatory expectations

Building upon the company’s success in organ preservation for liver transplantation, several new applications of the technology are now being actively developed. The successful candidate will join a rapidly growing Quality department working with R&D, Post-Market Engineering, Cybersecurity and Regulatory Affairs and play a key role in supporting compliance with EU MDR, FDA requirements and applicable software and cybersecurity standards, for new and existing products.

A central responsibility of the role is ensuring effective software risk management, particularly the development and maintenance of Software FMEAs (SFMEAs), software hazard analyses, cybersecurity risk assessments and associated risk controls

This is an onsite role in Oxford with flexibility.

Major Responsibilities

Under direction from the Software Quality Manager, the Software Quality Engineer will:

  • Assure software quality throughout the full lifecycle process in accordance with OrganOx software standards and procedures for software up to safety class C per IEC 62304.
  • Ensure effective implementation of software design controls, including requirements, architecture, verification and validation, configuration management, change control and release management.
  • Ensure appropriate traceability between software hazards, failure modes, software requirements, risk-control measures and verification evidence.
  • Ensure software FMEAs are aligned with system-level risk analyses, including system FMEAs, use-related risk analyses and the overall ISO 14971 risk-management file.
  • Review software lifecycle documentation for completeness, consistency, traceability and regulatory compliance.
  • Participate in design reviews, risk reviews, change assessments, project milestones and release-readiness reviews.
  • Provide Quality oversight of cybersecurity risk management, including threat modelling, vulnerability assessment, SOUP and third-party software.
  • Maintain and improve software procedures in line with IEC 62304, ISO 13485, ISO 14971, EU MDR, applicable FDA requirements and cybersecurity guidance.
  • Supporting Quality oversight of computer system validation/assurance (CSV)/CSA.
  • Ensure software defects, complaints, post-market information and cybersecurity vulnerabilities are assessed for their impact on the SFMEA and wider risk-management file.
  • Support software-related nonconformances, CAPAs, complaints, audits and regulatory inspections.
  • Contribute as part of the team to assist in other tasks as necessary.
  • Adhere to the letter and spirit of OrganOx’s Code of Conduct and all other company policies

Skills & Experience

  • Experience as a software quality engineer, or in a similar quality role, within the medical device industry, supporting SaMD, digital health applications or software in a medical device.
  • Experience developing, facilitating and reviewing SFMEAs and software hazard analyses for medical-device software under ISO 14971.
  • Experience reviewing software requirements, architecture, traceability, verification evidence, changes and release documentation.
  • Experience working in cybersecurity risk assessment (Desirable).
  • Experience in supporting, conducting, and reviewing activities and processes related to computer system validation (CSV).
  • Experience with GAMP5 classification used for CSV (Desirable).
  • Practical working knowledge of IEC 62304, ISO 14971, ISO 13485, EU MDR and applicable FDA software requirements and guidance.
  • Strong analytical and communication skills, with the ability to facilitate cross-functional risk discussions and constructively challenge technical decisions.
  • Experience working within a quality management system and following standard operating procedures.
  • Experience working in Quality within the medical device industry (Desirable).
  • Experience with SOUP, nonconformances, CAPA, complaints and regulatory audits (Desirable).
  • Knowledge of IEC 81001-5-1, IEC 82304-1 and FDA cybersecurity guidance (Desirable).

Qualifications

  • A degree or equivalent experience in software engineering, computer science, information engineering, systems engineering, quality engineering or a related discipline.

At OrganOx, we value innovation, evidence, integrity, teamwork, respect, and passion. We offer competitive compensation and comprehensive benefits, including healthcare and retirement plans. We support work-life balance and provide opportunities for ongoing professional development.

We are an equal opportunity employer, and all qualified applicants will receive consideration for employment without regard to age, disability, gender reassignment, marriage and civil partnership, pregnancy and maternity, race, religion or belief, sex, sexual orientation race, or any other characteristics protected by law.

Apply to OrganOx

Clera fills in OrganOx's application for you.

How it works

Open the role in Clera

Sign in, and this role opens on your Clera job board, ready to apply.

Clera fills in the application

Clera fills the form from your profile and resume, and asks what's missing.

Track it in Clera

Each application you send shows up in your Clera tracker, sorted by stage.

Want Clera to find roles for you?

Ask your AI about this role

It knows you. Clera gives it the role.

Does this role fit my profile?

First time? Connect Clera once, about a minute.
One click above pre-fills the connector. Or by hand: Settings > Connectors > Add custom connector, paste https://mcp.getclera.com. Either way, sign in with the account you use on Clera and approve the consent screen.
https://mcp.getclera.com

Sign in with your Clera account. MCP docs

About OrganOx

Transforming transplantation with the OrganOx metra®. A transportable, automated ex vivo liver perfusion device.

The core technology employed by the OrganOx metra® has been in development for over 15 years. During this time both of the founders (Professor Peter Friend and Professor Constantin Coussios) have driven the development of organ preservation and maintenance, formerly at the University of Cambridge and latterly at the University of Oxford.

OrganOx Limited was founded in April 2008 as a spin-out from the University of Oxford.

Conventional cold preservation involves storage of the liver at 4˚C, using a non-physiological perfusion solution that aims to minimise liver decay. By contrast, warm preservation seeks to re-create an environment that mimics the human body by continuously perfusing at physiological pressures and flows with oxygen-carrying red cells at 37˚C and providing nutrition. The liver is therefore functional during the preservation period, producing bile, metabolizing glucose and maintaining a physiological pH. This enables objective assessment of organ performance prior to transplant, extended preservation times, and the potential use of organs that are presently being discarded.

WARNING: OrganOx has been notified of various hiring scams using variations on our company’s name and e-mail address format. OrganOx will never use direct e-mail, phone calls, social media or chat tools to obtain personal information such as social security numbers, birth dates, etc. If you are concerned about questionable interactions with a purported OrganOx recruiter or hiring manager, please contact us at [email protected].

Team size
51-200 employees people
Founded
2008
Industry
Medical Equipment Manufacturing
Workplace
Hybrid
Locations
Oxford, England, United Kingdom

Benefits

  • Healthcare plans
  • Retirement plans
  • Professional development